-40%
Perseptive Biosystems Voyager-DE MALDI-TOF Mass Spectrometer Biospectrometry
$ 2481.07
- Description
- Size Guide
Description
Perseptive Biosystems Voyager-DE MALDI-TOF Mass Spectrometer BiospectrometryPlease Note the following:
FREE LOCAL PICK UP OR WE CAN ASSIST WITH SELECTION OF SH COMPANY VIA YOUR ACCOUNT
WE HAVE LOADING DOCKS AND FORKLIFT
Actual Picture of Unit
No accessories provided unless pictured.
If you have any questions regarding this item, please contact me _before_ bidding.
MANUFACTURE'S DETAILS:
High-performance benchtop Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) system for high quality data
Powerful Voyager Version 5 Software with Data Explorer™ for flexible acquisition and data processing
Reflectron provides high mass accuracy and post-source decay (PSD)
Fully automated acquisition and processing of data provides needed throughput
Integrated Microsoft® Visual Basic , for Applications (VBA) permits macro recording and customized processing routines
Optional collision-induced dissociation (CID) provides more structural information
The Voyager-DE™ PRO Biospectrometry™ Workstation is equipped with a reflecting ion mirror that boosts the resolution and mass accuracy over a large mass range. Post-source decay or PSD experiments are facilitated by the new Voyager Version 5 with Data Explorer™ software. Obtain even more structural information with the collision-induced dissociation (CID) option for enhanced fragmentation.
For Research Use Only. Not for Use in Diagnostic Procedures.
Specifications
Physical Specifications
Width 63.5 cm
Height 165.1 cm
Weight 450 lbs (204.3 kg)
Depth 76.2 cm
Technical Specifications
Resolution Linear For angiotensin I (m/z 1,296.6853)
For myoglobin I (m/z 16,952.5)
For BSA (m/z 66,431)
Mass accuracy linear, internal For angiotensin I (m/z 1,296.6853)
Mass accuracy, reflector, protein external For E. coli thioredoxin (m/z 11,674.4)
Mass accuracy linear, protein external For horse heart myoglobin (m/z 16,952.5)
Mass accuracy linear, external For angiotensin I (m/z 1,296.6853)
Mass accuracy, reflector, internal For human ACTH 18-39 (m/z 2,465.1989)
Mass accuracy, reflector, external For human ACTH 18-39 (m/z 2,465.1989)
Resolution Reflector For bovine insulin (m/z 5,734)
For E. coli thioredoxin (m/z 11,674.4)
For peptide mixture (m/z range 1,000-4,000)
Other Notes of Interest:
S&H :
Multiple items purchased will be considered for discounted shipping.
Expedited shipping can be arranged upon request.
All items will ship within 1 day of payment receipt.
Local Pick-up is Available
WAREHOUSE LOCATION
R